Energy Performance Certificate

Flat 3 Foxton House, 20, Broad Street, HR6 8BS

EPC Report

Energy rating

Current: 46 E | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 E Current: 46 E 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 32 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 69 Potential: 69
Field Value
LMK KEY 8676-7121-4390-1733-2902
ADDRESS1 Flat 3 Foxton House
ADDRESS2 20, Broad Street
ADDRESS3
POSTCODE HR6 8BS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 46
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2016-09-07
LOCAL AUTHORITY E06000019
CONSTITUENCY E14001395
COUNTY
LODGEMENT DATE 2016-09-09
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 897
ENERGY CONSUMPTION POTENTIAL 356
CO2 EMISSIONS CURRENT 4.1
CO2 EMISS CURR PER FLOOR AREA 152
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 24
LIGHTING COST POTENTIAL 24
HEATING COST CURRENT 604
HEATING COST POTENTIAL 181
HOT WATER COST CURRENT 147
HOT WATER COST POTENTIAL 147
TOTAL FLOOR AREA 27
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.26
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 3 Foxton House, 20, Broad Street
LOCAL AUTHORITY LABEL Herefordshire, County of
CONSTITUENCY LABEL North Herefordshire
POSTTOWN LEOMINSTER
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-09-09 11:22:11
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 200002616084
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000005
Address display
Nation ew