Energy Performance Certificate

54, Milburn Crescent, TS20 2DN

EPC Report

Energy rating

Current: 62 D | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 57 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 83 Potential: 83
Field Value
LMK KEY 8675-6922-7600-3320-2992
ADDRESS1 54, Milburn Crescent
ADDRESS2
ADDRESS3
POSTCODE TS20 2DN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-02-10
LOCAL AUTHORITY E06000004
CONSTITUENCY E14001518
COUNTY
LODGEMENT DATE 2015-02-11
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 312
ENERGY CONSUMPTION POTENTIAL 126
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 55
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 43
LIGHTING COST POTENTIAL 43
HEATING COST CURRENT 686
HEATING COST POTENTIAL 486
HOT WATER COST CURRENT 97
HOT WATER COST POTENTIAL 64
TOTAL FLOOR AREA 65
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.52
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 54, Milburn Crescent
LOCAL AUTHORITY LABEL Stockton-on-Tees
CONSTITUENCY LABEL Stockton North
POSTTOWN STOCKTON-ON-TEES
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-02-11 08:49:53
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100110188816
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000001
Address display
Nation ew