Energy Performance Certificate

13 Sunniholme Court, Warham Road, CR2 6LJ

EPC Report

Energy rating

Current: 36 F | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 F Current: 36 F 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 27 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 Current: 27 79 Potential: 79
Field Value
LMK KEY 8675-6325-5510-9822-8992
ADDRESS1 13 Sunniholme Court
ADDRESS2 Warham Road
ADDRESS3
POSTCODE CR2 6LJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 36
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2015-05-12
LOCAL AUTHORITY E09000008
CONSTITUENCY E14001188
COUNTY
LODGEMENT DATE 2015-06-13
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 27
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 583
ENERGY CONSUMPTION POTENTIAL 134
CO2 EMISSIONS CURRENT 7.2
CO2 EMISS CURR PER FLOOR AREA 99
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 78
LIGHTING COST POTENTIAL 50
HEATING COST CURRENT 691
HEATING COST POTENTIAL 295
HOT WATER COST CURRENT 651
HOT WATER COST POTENTIAL 116
TOTAL FLOOR AREA 73
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 58
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 58% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 5.65
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 13 Sunniholme Court, Warham Road
LOCAL AUTHORITY LABEL Croydon
CONSTITUENCY LABEL Croydon West
POSTTOWN SOUTH CROYDON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-06-13 10:10:41
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100020688377
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000007
Address display
Nation ew