Energy Performance Certificate

45, Talavera Way, SP9 7WH

EPC Report

Energy rating

Current: 85 B | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 B Current: 85 B 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 86 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 Current: 86 88 Potential: 88
Field Value
LMK KEY 8673-7635-5000-0190-8992
ADDRESS1 45, Talavera Way
ADDRESS2
ADDRESS3
POSTCODE SP9 7WH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 85
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2017-05-10
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001217
COUNTY
LODGEMENT DATE 2017-05-10
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 86
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 84
ENERGY CONSUMPTION POTENTIAL 69
CO2 EMISSIONS CURRENT 1.4
CO2 EMISS CURR PER FLOOR AREA 15
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 68
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 282
HEATING COST POTENTIAL 284
HOT WATER COST CURRENT 106
HOT WATER COST POTENTIAL 57
TOTAL FLOOR AREA 98
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.14 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.19 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.67
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 45, Talavera Way
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL East Wiltshire
POSTTOWN TIDWORTH
CONSTRUCTION AGE BAND 2017
LODGEMENT DATETIME 2017-05-10 12:22:09
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 10093280395
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2017.csv
COUNTRY England
REGION E12000009
Address display
Nation ew