Energy Performance Certificate

19, Central Drive, New Rossington, DN11 0JB

EPC Report

Energy rating

Current: 40 E | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 E Current: 40 E 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 37 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 Current: 37 87 Potential: 87
Field Value
LMK KEY 8667-7829-0239-9868-0902
ADDRESS1 19, Central Drive
ADDRESS2 New Rossington
ADDRESS3
POSTCODE DN11 0JB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 40
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2013-11-08
LOCAL AUTHORITY E08000017
CONSTITUENCY E14001199
COUNTY
LODGEMENT DATE 2013-11-08
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 37
ENVIRONMENT IMPACT POTENTIAL 87
ENERGY CONSUMPTION CURRENT 431
ENERGY CONSUMPTION POTENTIAL 74
CO2 EMISSIONS CURRENT 6.4
CO2 EMISS CURR PER FLOOR AREA 83
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 50
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 1057
HEATING COST POTENTIAL 400
HOT WATER COST CURRENT 207
HOT WATER COST POTENTIAL 70
TOTAL FLOOR AREA 77
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and boiler energy manager
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 89
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazeddouble glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and boiler energy manager
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 89% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.42
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 19, Central Drive, New Rossington
LOCAL AUTHORITY LABEL Doncaster
CONSTITUENCY LABEL Doncaster East and the Isle of Axholme
POSTTOWN DONCASTER
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2013-11-08 09:40:45
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100050707349
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000003
Address display
Nation ew