Energy Performance Certificate

89, Windermere Road, LA1 3EZ

EPC Report

Energy rating

Current: 38 F | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 F Current: 38 F 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 36 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 Current: 36 81 Potential: 81
Field Value
LMK KEY 8662-6126-9000-6902-9996
ADDRESS1 89, Windermere Road
ADDRESS2
ADDRESS3
POSTCODE LA1 3EZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 38
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2012-06-12
LOCAL AUTHORITY E07000121
CONSTITUENCY E14001318
COUNTY
LODGEMENT DATE 2012-06-12
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 36
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 438
ENERGY CONSUMPTION POTENTIAL 100
CO2 EMISSIONS CURRENT 5.7
CO2 EMISS CURR PER FLOOR AREA 89
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 55
LIGHTING COST POTENTIAL 37
HEATING COST CURRENT 811
HEATING COST POTENTIAL 418
HOT WATER COST CURRENT 253
HOT WATER COST POTENTIAL 62
TOTAL FLOOR AREA 64
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 89, Windermere Road
LOCAL AUTHORITY LABEL Lancaster
CONSTITUENCY LABEL Lancaster and Wyre
POSTTOWN LANCASTER
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2012-06-12 12:37:38
TENURE
FIXED LIGHTING OUTLETS COUNT 2
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100010478711
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000002
Address display
Nation ew