Energy Performance Certificate

Tanglewood, Main Road, Cutthorpe, S42 7AG

EPC Report

Energy rating

Current: 61 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 55 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 Current: 55 75 Potential: 75
Field Value
LMK KEY 8661-7425-6040-6468-1906
ADDRESS1 Tanglewood
ADDRESS2 Main Road
ADDRESS3 Cutthorpe
POSTCODE S42 7AG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2019-05-08
LOCAL AUTHORITY E07000038
CONSTITUENCY E14001391
COUNTY
LODGEMENT DATE 2019-05-11
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 55
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 249
ENERGY CONSUMPTION POTENTIAL 137
CO2 EMISSIONS CURRENT 7.6
CO2 EMISS CURR PER FLOOR AREA 44
CO2 EMISSIONS POTENTIAL 4.2
LIGHTING COST CURRENT 175
LIGHTING COST POTENTIAL 95
HEATING COST CURRENT 1456
HEATING COST POTENTIAL 987
HOT WATER COST CURRENT 98
HOT WATER COST POTENTIAL 99
TOTAL FLOOR AREA 173
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 90
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 15
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 15% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Tanglewood, Main Road, Cutthorpe
LOCAL AUTHORITY LABEL North East Derbyshire
CONSTITUENCY LABEL North East Derbyshire
POSTTOWN CHESTERFIELD
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2019-05-11 07:01:21
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100030205489
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000004
Address display
Nation ew