Energy Performance Certificate

130, Barton Road, Comberton, CB23 7BT

EPC Report

Energy rating

Current: 62 D | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 66 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 Current: 66 78 Potential: 78
Field Value
LMK KEY 8655-7327-0480-2894-1926
ADDRESS1 130, Barton Road
ADDRESS2 Comberton
ADDRESS3
POSTCODE CB23 7BT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-03-24
LOCAL AUTHORITY E07000012
CONSTITUENCY E14001481
COUNTY
LODGEMENT DATE 2015-03-26
TRANSACTION TYPE RHI application
ENVIRONMENT IMPACT CURRENT 66
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 209
ENERGY CONSUMPTION POTENTIAL 129
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 35
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 63
LIGHTING COST POTENTIAL 63
HEATING COST CURRENT 618
HEATING COST POTENTIAL 620
HOT WATER COST CURRENT 365
HOT WATER COST POTENTIAL 245
TOTAL FLOOR AREA 102
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.42
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 130, Barton Road, Comberton
LOCAL AUTHORITY LABEL South Cambridgeshire
CONSTITUENCY LABEL South Cambridgeshire
POSTTOWN CAMBRIDGE
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2015-03-26 16:20:26
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100090131859
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display
Nation ew