Energy Performance Certificate

Nyth y Wylan, Lon Isallt, Trearddur Bay, LL65 2UP

EPC Report

Energy rating

Current: 79 C | Potential: 101 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 101 A Potential: 101 A

Environmental impact (CO₂)

Current: 81 | Potential: 101
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 81 Current: 81 101 Potential: 101
Field Value
LMK KEY 8653-7831-0350-6486-1906
ADDRESS1 Nyth y Wylan
ADDRESS2 Lon Isallt
ADDRESS3 Trearddur Bay
POSTCODE LL65 2UP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 79
POTENTIAL ENERGY EFFICIENCY 101
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2017-09-06
LOCAL AUTHORITY W06000001
CONSTITUENCY W07000112
COUNTY
LODGEMENT DATE 2017-09-06
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 81
ENVIRONMENT IMPACT POTENTIAL 101
ENERGY CONSUMPTION CURRENT 118
ENERGY CONSUMPTION POTENTIAL 4
CO2 EMISSIONS CURRENT 3.2
CO2 EMISS CURR PER FLOOR AREA 20
CO2 EMISSIONS POTENTIAL 0.1
LIGHTING COST CURRENT 81
LIGHTING COST POTENTIAL 81
HEATING COST CURRENT 712
HEATING COST POTENTIAL 712
HOT WATER COST CURRENT 159
HOT WATER COST POTENTIAL 96
TOTAL FLOOR AREA 159
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.17 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.21 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.15 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Ground source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Nyth y Wylan, Lon Isallt, Trearddur Bay
LOCAL AUTHORITY LABEL Isle of Anglesey
CONSTITUENCY LABEL Ynys Môn
POSTTOWN HOLYHEAD
CONSTRUCTION AGE BAND 2015
LODGEMENT DATETIME 2017-09-06 16:51:04
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 42
LOW ENERGY FIXED LIGHT COUNT 42
UPRN 10013461951
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2017.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew