Energy Performance Certificate

53, Church Road, EN6 1EY

EPC Report

Energy rating

Current: 63 D | Potential: 63 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 63 D Potential: 63 D

Environmental impact (CO₂)

Current: 67 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 Current: 67 67 Potential: 67
Field Value
LMK KEY 8648-7432-5230-0545-4902
ADDRESS1 53, Church Road
ADDRESS2
ADDRESS3
POSTCODE EN6 1EY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 63
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-02-05
LOCAL AUTHORITY E07000098
CONSTITUENCY E14001284
COUNTY
LODGEMENT DATE 2018-02-05
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 67
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 380
ENERGY CONSUMPTION POTENTIAL 380
CO2 EMISSIONS CURRENT 1.7
CO2 EMISS CURR PER FLOOR AREA 64
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 33
LIGHTING COST POTENTIAL 33
HEATING COST CURRENT 301
HEATING COST POTENTIAL 301
HOT WATER COST CURRENT 201
HOT WATER COST POTENTIAL 201
TOTAL FLOOR AREA 27
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Average thermal transmittance 0.11 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.30 W/m²K
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.16 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.56
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 53, Church Road
LOCAL AUTHORITY LABEL Hertsmere
CONSTITUENCY LABEL Hertsmere
POSTTOWN POTTERS BAR
CONSTRUCTION AGE BAND 2017
LODGEMENT DATETIME 2018-02-05 09:13:55
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 4
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 10034170091
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2018.csv
COUNTRY England
REGION E12000006
Address display
Nation ew