Energy Performance Certificate

37, Crossmead, SE9 3AA

EPC Report

Energy rating

Current: 40 E | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 E Current: 40 E 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 33 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 71 Potential: 71
Field Value
LMK KEY 8645-7228-3420-2872-5992
ADDRESS1 37, Crossmead
ADDRESS2
ADDRESS3
POSTCODE SE9 3AA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 40
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-08-12
LOCAL AUTHORITY E09000011
CONSTITUENCY E14001223
COUNTY
LODGEMENT DATE 2015-08-12
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 404
ENERGY CONSUMPTION POTENTIAL 137
CO2 EMISSIONS CURRENT 7.8
CO2 EMISS CURR PER FLOOR AREA 71
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 113
LIGHTING COST POTENTIAL 65
HEATING COST CURRENT 1390
HEATING COST POTENTIAL 703
HOT WATER COST CURRENT 179
HOT WATER COST POTENTIAL 79
TOTAL FLOOR AREA 109
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 27
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 27% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.59
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 37, Crossmead
LOCAL AUTHORITY LABEL Greenwich
CONSTITUENCY LABEL Eltham and Chislehurst
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2015-08-12 10:42:43
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100020955421
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000007
Address display
Nation ew