Energy Performance Certificate

3, Brockhill Way, CF64 5QD

EPC Report

Energy rating

Current: 63 D | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 54 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 Current: 54 80 Potential: 80
Field Value
LMK KEY 8645-7129-3530-3103-7906
ADDRESS1 3, Brockhill Way
ADDRESS2
ADDRESS3
POSTCODE CF64 5QD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-01-07
LOCAL AUTHORITY W06000014
CONSTITUENCY W07000091
COUNTY
LODGEMENT DATE 2015-01-07
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 54
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 219
ENERGY CONSUMPTION POTENTIAL 87
CO2 EMISSIONS CURRENT 6.7
CO2 EMISS CURR PER FLOOR AREA 39
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 122
LIGHTING COST POTENTIAL 84
HEATING COST CURRENT 1133
HEATING COST POTENTIAL 706
HOT WATER COST CURRENT 204
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 174
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 54
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 25 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 54% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.32
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, Brockhill Way
LOCAL AUTHORITY LABEL Vale of Glamorgan
CONSTITUENCY LABEL Cardiff South and Penarth
POSTTOWN PENARTH
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2015-01-07 18:53:19
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 26
LOW ENERGY FIXED LIGHT COUNT 14
UPRN 100100837127
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew