Energy Performance Certificate

The Cottage, Cross Green, Hartest, IP29 4EF

EPC Report

Energy rating

Current: 18 G | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 18 G Current: 18 G 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 19 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 19 Current: 19 64 Potential: 64
Field Value
LMK KEY 8635-7628-3540-9823-3922
ADDRESS1 The Cottage
ADDRESS2 Cross Green
ADDRESS3 Hartest
POSTCODE IP29 4EF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 18
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-08-27
LOCAL AUTHORITY E07000200
CONSTITUENCY E14001494
COUNTY
LODGEMENT DATE 2015-08-28
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 19
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 435
ENERGY CONSUMPTION POTENTIAL 102
CO2 EMISSIONS CURRENT 13
CO2 EMISS CURR PER FLOOR AREA 109
CO2 EMISSIONS POTENTIAL 4.3
LIGHTING COST CURRENT 128
LIGHTING COST POTENTIAL 70
HEATING COST CURRENT 2169
HEATING COST POTENTIAL 1272
HOT WATER COST CURRENT 322
HOT WATER COST POTENTIAL 97
TOTAL FLOOR AREA 122
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 15
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 14
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Timber frame, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 14% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.15
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS The Cottage, Cross Green, Hartest
LOCAL AUTHORITY LABEL Babergh
CONSTITUENCY LABEL South Suffolk
POSTTOWN BURY ST. EDMUNDS
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-08-28 10:06:43
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 10013101463
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display