Energy Performance Certificate

130a Far Gosford Street, CV1 5EA

EPC Report

Energy rating

Current: 22 F | Potential: 50 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 F Current: 22 F 50 E Potential: 50 E

Environmental impact (CO₂)

Current: 33 | Potential: 33
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 33 Potential: 33
Field Value
LMK KEY 8633-7426-5190-7284-7922
ADDRESS1 130a Far Gosford Street
ADDRESS2
ADDRESS3
POSTCODE CV1 5EA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 22
POTENTIAL ENERGY EFFICIENCY 50
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2017-06-24
LOCAL AUTHORITY E08000026
CONSTITUENCY E14001182
COUNTY
LODGEMENT DATE 2017-06-28
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 33
ENERGY CONSUMPTION CURRENT 598
ENERGY CONSUMPTION POTENTIAL 601
CO2 EMISSIONS CURRENT 5.6
CO2 EMISS CURR PER FLOOR AREA 101
CO2 EMISSIONS POTENTIAL 5.6
LIGHTING COST CURRENT 40
LIGHTING COST POTENTIAL 45
HEATING COST CURRENT 1468
HEATING COST POTENTIAL 778
HOT WATER COST CURRENT 171
HOT WATER COST POTENTIAL 189
TOTAL FLOOR AREA 55
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 130a Far Gosford Street
LOCAL AUTHORITY LABEL Coventry
CONSTITUENCY LABEL Coventry South
POSTTOWN COVENTRY
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2017-06-28 09:33:17
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 10094852419
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000005
Address display