Energy Performance Certificate

4, Romney Road, Rottingdean, BN2 7GG

EPC Report

Energy rating

Current: 44 E | Potential: 65 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 E Current: 44 E 65 D Potential: 65 D

Environmental impact (CO₂)

Current: 40 | Potential: 59
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 Current: 40 59 Potential: 59
Field Value
LMK KEY 8633-6923-9480-3459-2972
ADDRESS1 4, Romney Road
ADDRESS2 Rottingdean
ADDRESS3
POSTCODE BN2 7GG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 44
POTENTIAL ENERGY EFFICIENCY 65
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2017-07-31
LOCAL AUTHORITY E06000043
CONSTITUENCY E14001129
COUNTY
LODGEMENT DATE 2017-08-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 40
ENVIRONMENT IMPACT POTENTIAL 59
ENERGY CONSUMPTION CURRENT 370
ENERGY CONSUMPTION POTENTIAL 222
CO2 EMISSIONS CURRENT 6.1
CO2 EMISS CURR PER FLOOR AREA 65
CO2 EMISSIONS POTENTIAL 3.7
LIGHTING COST CURRENT 116
LIGHTING COST POTENTIAL 61
HEATING COST CURRENT 1162
HEATING COST POTENTIAL 983
HOT WATER COST CURRENT 153
HOT WATER COST POTENTIAL 83
TOTAL FLOOR AREA 95
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 67
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 10
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 10% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.57
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4, Romney Road, Rottingdean
LOCAL AUTHORITY LABEL Brighton and Hove
CONSTITUENCY LABEL Brighton Kemptown and Peacehaven
POSTTOWN BRIGHTON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2017-08-01 11:54:07
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 22109423
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000008
Address display
Nation ew