Energy Performance Certificate

3, Brook Terrace, Mochdre Lane, SY16 4JG

EPC Report

Energy rating

Current: 51 E | Potential: 94 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 E Current: 51 E 94 A Potential: 94 A

Environmental impact (CO₂)

Current: 43 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 Current: 43 88 Potential: 88
Field Value
LMK KEY 8632-7228-0930-8161-9922
ADDRESS1 3, Brook Terrace
ADDRESS2 Mochdre Lane
ADDRESS3
POSTCODE SY16 4JG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 51
POTENTIAL ENERGY EFFICIENCY 94
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2012-08-29
LOCAL AUTHORITY W06000023
CONSTITUENCY W07000102
COUNTY
LODGEMENT DATE 2012-08-30
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 43
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 352
ENERGY CONSUMPTION POTENTIAL 56
CO2 EMISSIONS CURRENT 5.0
CO2 EMISS CURR PER FLOOR AREA 69
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 50
LIGHTING COST POTENTIAL 50
HEATING COST CURRENT 653
HEATING COST POTENTIAL 265
HOT WATER COST CURRENT 306
HOT WATER COST POTENTIAL 114
TOTAL FLOOR AREA 73
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 50
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial secondary glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, dual fuel (mineral and wood)
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.28
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, Brook Terrace, Mochdre Lane
LOCAL AUTHORITY LABEL Powys
CONSTITUENCY LABEL Montgomeryshire and Glyndwr
POSTTOWN NEWTOWN
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2012-08-30 10:17:04
TENURE
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 10011778872
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew