Energy Performance Certificate

297, Preston Road, HA3 0QQ

EPC Report

Energy rating

Current: 55 D | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 D Current: 55 D 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 44 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 Current: 44 75 Potential: 75
Field Value
LMK KEY 8631-7129-0049-1691-8992
ADDRESS1 297, Preston Road
ADDRESS2
ADDRESS3
POSTCODE HA3 0QQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 55
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2019-11-19
LOCAL AUTHORITY E09000005
CONSTITUENCY E14001123
COUNTY
LODGEMENT DATE 2019-11-20
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 44
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 278
ENERGY CONSUMPTION POTENTIAL 112
CO2 EMISSIONS CURRENT 9.1
CO2 EMISS CURR PER FLOOR AREA 49
CO2 EMISSIONS POTENTIAL 3.7
LIGHTING COST CURRENT 103
LIGHTING COST POTENTIAL 103
HEATING COST CURRENT 1601
HEATING COST POTENTIAL 783
HOT WATER COST CURRENT 107
HOT WATER COST POTENTIAL 107
TOTAL FLOOR AREA 186
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 83
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 11
NUMBER HEATED ROOMS 11
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.62
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 297, Preston Road
LOCAL AUTHORITY LABEL Brent
CONSTITUENCY LABEL Brent West
POSTTOWN HARROW
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2019-11-20 19:59:18
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 202054823
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000007
Address display