Energy Performance Certificate

23, Lanehouse Road, Thornaby, TS17 8AF

EPC Report

Energy rating

Current: 61 D | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 54 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 Current: 54 82 Potential: 82
Field Value
LMK KEY 8616-7729-0100-0176-0922
ADDRESS1 23, Lanehouse Road
ADDRESS2 Thornaby
ADDRESS3
POSTCODE TS17 8AF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-01-26
LOCAL AUTHORITY E06000004
CONSTITUENCY E14001367
COUNTY
LODGEMENT DATE 2016-01-26
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 54
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 282
ENERGY CONSUMPTION POTENTIAL 104
CO2 EMISSIONS CURRENT 4.9
CO2 EMISS CURR PER FLOOR AREA 50
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 84
LIGHTING COST POTENTIAL 61
HEATING COST CURRENT 902
HEATING COST POTENTIAL 534
HOT WATER COST CURRENT 111
HOT WATER COST POTENTIAL 75
TOTAL FLOOR AREA 98
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 62
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 62% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.95
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 23, Lanehouse Road, Thornaby
LOCAL AUTHORITY LABEL Stockton-on-Tees
CONSTITUENCY LABEL Middlesbrough and Thornaby East
POSTTOWN STOCKTON-ON-TEES
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2016-01-26 14:52:08
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100110184283
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000001
Address display
Nation ew