Energy Performance Certificate

3, Trellis Drive, Lychpit, RG24 8YU

EPC Report

Energy rating

Current: 59 D | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 51 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 Current: 51 84 Potential: 84
Field Value
LMK KEY 8616-7527-4830-7331-8926
ADDRESS1 3, Trellis Drive
ADDRESS2 Lychpit
ADDRESS3
POSTCODE RG24 8YU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-03-29
LOCAL AUTHORITY E07000084
CONSTITUENCY E14001392
COUNTY
LODGEMENT DATE 2016-03-30
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 51
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 287
ENERGY CONSUMPTION POTENTIAL 81
CO2 EMISSIONS CURRENT 4.9
CO2 EMISS CURR PER FLOOR AREA 51
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 63
LIGHTING COST POTENTIAL 63
HEATING COST CURRENT 866
HEATING COST POTENTIAL 468
HOT WATER COST CURRENT 184
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 98
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, Trellis Drive, Lychpit
LOCAL AUTHORITY LABEL Basingstoke and Deane
CONSTITUENCY LABEL North East Hampshire
POSTTOWN BASINGSTOKE
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2016-03-30 08:06:14
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 17
UPRN 100062461699
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000008
Address display
Nation ew