Energy Performance Certificate

Brimir, Escrick Road, Stillingfleet, YO19 6SD

EPC Report

Energy rating

Current: 62 D | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 36 | Potential: 59
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 Current: 36 59 Potential: 59
Field Value
LMK KEY 8616-7526-4330-4582-5922
ADDRESS1 Brimir
ADDRESS2 Escrick Road
ADDRESS3 Stillingfleet
POSTCODE YO19 6SD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2016-06-22
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001464
COUNTY
LODGEMENT DATE 2016-06-22
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 36
ENVIRONMENT IMPACT POTENTIAL 59
ENERGY CONSUMPTION CURRENT 363
ENERGY CONSUMPTION POTENTIAL 207
CO2 EMISSIONS CURRENT 16
CO2 EMISS CURR PER FLOOR AREA 63
CO2 EMISSIONS POTENTIAL 9.0
LIGHTING COST CURRENT 143
LIGHTING COST POTENTIAL 143
HEATING COST CURRENT 1989
HEATING COST POTENTIAL 1392
HOT WATER COST CURRENT 174
HOT WATER COST POTENTIAL 174
TOTAL FLOOR AREA 252
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE triple glazing
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 11
NUMBER HEATED ROOMS 11
LOW ENERGY LIGHTING 82
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully triple glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 82% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Brimir, Escrick Road, Stillingfleet
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Selby
POSTTOWN YORK
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2016-06-22 16:14:54
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 33
LOW ENERGY FIXED LIGHT COUNT 27
UPRN 200001020128
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000003
Address display
Nation ew