Energy Performance Certificate

26, Victoria Road, KT1 3DW

EPC Report

Energy rating

Current: 50 E | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 E Current: 50 E 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 46 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 70 Potential: 70
Field Value
LMK KEY 8608-6322-7830-9162-1926
ADDRESS1 26, Victoria Road
ADDRESS2
ADDRESS3
POSTCODE KT1 3DW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 50
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2018-02-22
LOCAL AUTHORITY E09000021
CONSTITUENCY E14001312
COUNTY
LODGEMENT DATE 2018-02-22
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 265
ENERGY CONSUMPTION POTENTIAL 132
CO2 EMISSIONS CURRENT 9.8
CO2 EMISS CURR PER FLOOR AREA 42
CO2 EMISSIONS POTENTIAL 4.8
LIGHTING COST CURRENT 162
LIGHTING COST POTENTIAL 103
HEATING COST CURRENT 1930
HEATING COST POTENTIAL 1107
HOT WATER COST CURRENT 146
HOT WATER COST POTENTIAL 147
TOTAL FLOOR AREA 230
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 65
GLAZED TYPE double glazing installed before 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 42
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 42% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.97
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 26, Victoria Road
LOCAL AUTHORITY LABEL Kingston upon Thames
CONSTITUENCY LABEL Kingston and Surbiton
POSTTOWN KINGSTON UPON THAMES
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2018-02-22 16:16:46
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 36
LOW ENERGY FIXED LIGHT COUNT 15
UPRN 128029038
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000007
Address display
Nation ew