Energy Performance Certificate

84, Victoria Road North, PO5 1QA

EPC Report

Energy rating

Current: 37 F | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 F Current: 37 F 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 32 | Potential: 61
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 61 Potential: 61
Field Value
LMK KEY 8608-4903-1829-6097-8153
ADDRESS1 84, Victoria Road North
ADDRESS2
ADDRESS3
POSTCODE PO5 1QA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 37
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-09-10
LOCAL AUTHORITY E06000044
CONSTITUENCY E14001432
COUNTY
LODGEMENT DATE 2015-09-15
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 61
ENERGY CONSUMPTION CURRENT 351
ENERGY CONSUMPTION POTENTIAL 163
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 62
CO2 EMISSIONS POTENTIAL 5.5
LIGHTING COST CURRENT 177
LIGHTING COST POTENTIAL 89
HEATING COST CURRENT 2311
HEATING COST POTENTIAL 1217
HOT WATER COST CURRENT 114
HOT WATER COST POTENTIAL 116
TOTAL FLOOR AREA 190
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 60
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 84, Victoria Road North
LOCAL AUTHORITY LABEL Portsmouth
CONSTITUENCY LABEL Portsmouth South
POSTTOWN SOUTHSEA
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-09-15 11:27:04
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 22
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 1775081568
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000008
Address display
Nation ew