Energy Performance Certificate

4, The Arbour, SG13 8AS

EPC Report

Energy rating

Current: 76 C | Potential: 99 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 C Current: 76 C 99 A Potential: 99 A

Environmental impact (CO₂)

Current: 58 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 Current: 58 90 Potential: 90
Field Value
LMK KEY 8607-8460-5929-6407-5263
ADDRESS1 4, The Arbour
ADDRESS2
ADDRESS3
POSTCODE SG13 8AS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 76
POTENTIAL ENERGY EFFICIENCY 99
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-02-06
LOCAL AUTHORITY E07000242
CONSTITUENCY E14001283
COUNTY
LODGEMENT DATE 2016-02-06
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 58
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 195
ENERGY CONSUMPTION POTENTIAL 22
CO2 EMISSIONS CURRENT 4.8
CO2 EMISS CURR PER FLOOR AREA 36
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 122
LIGHTING COST POTENTIAL 75
HEATING COST CURRENT 1547
HEATING COST POTENTIAL 849
HOT WATER COST CURRENT 203
HOT WATER COST POTENTIAL 106
TOTAL FLOOR AREA 135
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 35
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Warm air, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 35% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4, The Arbour
LOCAL AUTHORITY LABEL East Hertfordshire
CONSTITUENCY LABEL Hertford and Stortford
POSTTOWN HERTFORD
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2016-02-06 13:44:32
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100080740163
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000006
Address display
Nation ew