Energy Performance Certificate

86, Dowry Street, BB5 1AW

EPC Report

Energy rating

Current: 34 F | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 F Current: 34 F 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 34 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 Current: 34 65 Potential: 65
Field Value
LMK KEY 8607-7702-2122-8897-2903
ADDRESS1 86, Dowry Street
ADDRESS2
ADDRESS3
POSTCODE BB5 1AW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 34
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2020-01-10
LOCAL AUTHORITY E07000120
CONSTITUENCY E14001299
COUNTY
LODGEMENT DATE 2020-01-31
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 34
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 574
ENERGY CONSUMPTION POTENTIAL 279
CO2 EMISSIONS CURRENT 6.6
CO2 EMISS CURR PER FLOOR AREA 97
CO2 EMISSIONS POTENTIAL 3.2
LIGHTING COST CURRENT 86
LIGHTING COST POTENTIAL 62
HEATING COST CURRENT 1439
HEATING COST POTENTIAL 642
HOT WATER COST CURRENT 315
HOT WATER COST POTENTIAL 111
TOTAL FLOOR AREA 68
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 50
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 38
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 38% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 86, Dowry Street
LOCAL AUTHORITY LABEL Hyndburn
CONSTITUENCY LABEL Hyndburn
POSTTOWN ACCRINGTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2020-01-31 10:43:00
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100010428242
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000002
Address display
Nation ew