Energy Performance Certificate

59 Boston Towers, LS9 7PB

EPC Report

Energy rating

Current: 67 D | Potential: 67 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 67 D Potential: 67 D

Environmental impact (CO₂)

Current: 147 | Potential: 147
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 147 Current: 147 147 Potential: 147
Field Value
LMK KEY 8606-9299-9939-7596-0183
ADDRESS1 59 Boston Towers
ADDRESS2
ADDRESS3
POSTCODE LS9 7PB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 67
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2018-09-11
LOCAL AUTHORITY E08000035
CONSTITUENCY E14001323
COUNTY
LODGEMENT DATE 2019-10-24
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 147
ENVIRONMENT IMPACT POTENTIAL 147
ENERGY CONSUMPTION CURRENT 118
ENERGY CONSUMPTION POTENTIAL 118
CO2 EMISSIONS CURRENT -3.4
CO2 EMISS CURR PER FLOOR AREA -62.6
CO2 EMISSIONS POTENTIAL -3.4
LIGHTING COST CURRENT 48
LIGHTING COST POTENTIAL 48
HEATING COST CURRENT 472
HEATING COST POTENTIAL 472
HOT WATER COST CURRENT 68
HOT WATER COST POTENTIAL 68
TOTAL FLOOR AREA 54
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT
MAIN HEATING CONTROLS Charging system linked to use of community heating, programmer and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 0.87 W/m²K
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 2.3 W/m²K
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 59 Boston Towers
LOCAL AUTHORITY LABEL Leeds
CONSTITUENCY LABEL Leeds South
POSTTOWN LEEDS
CONSTRUCTION AGE BAND 2018
LODGEMENT DATETIME 2019-10-24 09:42:38
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 72121031
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2019.csv
COUNTRY England
REGION E12000003
Address display
Nation ew