Energy Performance Certificate

16, Mary Ruck Way, Black Notley, CM77 8RA

EPC Report

Energy rating

Current: 68 D | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 D Current: 68 D 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 62 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 Current: 62 80 Potential: 80
Field Value
LMK KEY 8606-7724-4100-9385-4906
ADDRESS1 16, Mary Ruck Way
ADDRESS2 Black Notley
ADDRESS3
POSTCODE CM77 8RA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 68
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2016-04-05
LOCAL AUTHORITY E07000067
CONSTITUENCY E14001121
COUNTY
LODGEMENT DATE 2016-04-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 62
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 202
ENERGY CONSUMPTION POTENTIAL 98
CO2 EMISSIONS CURRENT 5.2
CO2 EMISS CURR PER FLOOR AREA 36
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 90
LIGHTING COST POTENTIAL 90
HEATING COST CURRENT 849
HEATING COST POTENTIAL 665
HOT WATER COST CURRENT 232
HOT WATER COST POTENTIAL 81
TOTAL FLOOR AREA 146
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 90
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 90% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 16, Mary Ruck Way, Black Notley
LOCAL AUTHORITY LABEL Braintree
CONSTITUENCY LABEL Braintree
POSTTOWN BRAINTREE
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2016-04-05 16:30:52
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 21
LOW ENERGY FIXED LIGHT COUNT 19
UPRN 10006920028
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000006
Address display
Nation ew