Energy Performance Certificate

11, Albany Road, RM18 7BF

EPC Report

Energy rating

Current: 68 D | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 D Current: 68 D 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 52 | Potential: 58
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 Current: 52 58 Potential: 58
Field Value
LMK KEY 8606-2215-5429-3527-2133
ADDRESS1 11, Albany Road
ADDRESS2
ADDRESS3
POSTCODE RM18 7BF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 68
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2017-09-29
LOCAL AUTHORITY E06000034
CONSTITUENCY E14001546
COUNTY
LODGEMENT DATE 2017-09-30
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 52
ENVIRONMENT IMPACT POTENTIAL 58
ENERGY CONSUMPTION CURRENT 392
ENERGY CONSUMPTION POTENTIAL 340
CO2 EMISSIONS CURRENT 2.9
CO2 EMISS CURR PER FLOOR AREA 66
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 67
LIGHTING COST POTENTIAL 37
HEATING COST CURRENT 326
HEATING COST POTENTIAL 259
HOT WATER COST CURRENT 130
HOT WATER COST POTENTIAL 130
TOTAL FLOOR AREA 44
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 20
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 20% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 4.64
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11, Albany Road
LOCAL AUTHORITY LABEL Thurrock
CONSTITUENCY LABEL Thurrock
POSTTOWN TILBURY
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2017-09-30 08:54:15
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100090760695
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000006
Address display
Nation ew