Energy Performance Certificate

Plymstock, Symonds Yat, HR9 6BL

EPC Report

Energy rating

Current: 44 E | Potential: 56 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 E Current: 44 E 56 D Potential: 56 D

Environmental impact (CO₂)

Current: 58 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 Current: 58 68 Potential: 68
Field Value
LMK KEY 8605-6545-2129-8507-6533
ADDRESS1 Plymstock
ADDRESS2 Symonds Yat
ADDRESS3
POSTCODE HR9 6BL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 44
POTENTIAL ENERGY EFFICIENCY 56
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2017-05-04
LOCAL AUTHORITY E06000019
CONSTITUENCY E14001281
COUNTY
LODGEMENT DATE 2017-05-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 58
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 167
ENERGY CONSUMPTION POTENTIAL 118
CO2 EMISSIONS CURRENT 6.9
CO2 EMISS CURR PER FLOOR AREA 36
CO2 EMISSIONS POTENTIAL 5.1
LIGHTING COST CURRENT 89
LIGHTING COST POTENTIAL 89
HEATING COST CURRENT 1695
HEATING COST POTENTIAL 1531
HOT WATER COST CURRENT 178
HOT WATER COST POTENTIAL 117
TOTAL FLOOR AREA 189
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, LPG
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL LPG (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.34
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Plymstock, Symonds Yat
LOCAL AUTHORITY LABEL Herefordshire, County of
CONSTITUENCY LABEL Hereford and South Herefordshire
POSTTOWN ROSS-ON-WYE
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2017-05-10 10:08:58
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 21
LOW ENERGY FIXED LIGHT COUNT 21
UPRN 10009564951
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000005
Address display
Nation ew