Energy Performance Certificate

32, Dunstal Field, Cottenham, CB24 8UH

EPC Report

Energy rating

Current: 58 D | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 53 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 78 Potential: 78
Field Value
LMK KEY 8604-6428-4790-7883-2926
ADDRESS1 32, Dunstal Field
ADDRESS2 Cottenham
ADDRESS3
POSTCODE CB24 8UH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2014-08-27
LOCAL AUTHORITY E07000012
CONSTITUENCY E14001224
COUNTY
LODGEMENT DATE 2014-08-27
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 224
ENERGY CONSUMPTION POTENTIAL 99
CO2 EMISSIONS CURRENT 7.8
CO2 EMISS CURR PER FLOOR AREA 43
CO2 EMISSIONS POTENTIAL 3.5
LIGHTING COST CURRENT 104
LIGHTING COST POTENTIAL 106
HEATING COST CURRENT 1514
HEATING COST POTENTIAL 986
HOT WATER COST CURRENT 204
HOT WATER COST POTENTIAL 95
TOTAL FLOOR AREA 184
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 50
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 32, Dunstal Field, Cottenham
LOCAL AUTHORITY LABEL South Cambridgeshire
CONSTITUENCY LABEL Ely and East Cambridgeshire
POSTTOWN CAMBRIDGE
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2014-08-27 15:08:00
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 15
UPRN 100090138861
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000006
Address display
Nation ew