Energy Performance Certificate

5, Victoria Court, Victoria Street, ME16 8JZ

EPC Report

Energy rating

Current: 67 D | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 49 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 69 Potential: 69
Field Value
LMK KEY 8601-2486-9822-5107-9903
ADDRESS1 5, Victoria Court
ADDRESS2 Victoria Street
ADDRESS3
POSTCODE ME16 8JZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2020-01-08
LOCAL AUTHORITY E07000110
CONSTITUENCY E14001349
COUNTY
LODGEMENT DATE 2020-01-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 452
ENERGY CONSUMPTION POTENTIAL 274
CO2 EMISSIONS CURRENT 3
CO2 EMISS CURR PER FLOOR AREA 76
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 77
LIGHTING COST POTENTIAL 39
HEATING COST CURRENT 372
HEATING COST POTENTIAL 173
HOT WATER COST CURRENT 175
HOT WATER COST POTENTIAL 149
TOTAL FLOOR AREA 39
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH 0
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Victoria Court, Victoria Street
LOCAL AUTHORITY LABEL Maidstone
CONSTITUENCY LABEL Maidstone and Malling
POSTTOWN MAIDSTONE
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2020-01-08 17:56:10
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 200003668692
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000008
Address display
Nation ew