Energy Performance Certificate

61 Meadow View Road, Kennington, OX1 5QX

EPC Report

Energy rating

Current: 58 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 40 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 Current: 40 64 Potential: 64
Field Value
LMK KEY 8600-4596-0522-6291-3573
ADDRESS1 61 Meadow View Road
ADDRESS2 Kennington
ADDRESS3
POSTCODE OX1 5QX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2023-05-11
LOCAL AUTHORITY E07000180
CONSTITUENCY E14001420
COUNTY
LODGEMENT DATE 2023-05-11
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 40
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 410
ENERGY CONSUMPTION POTENTIAL 214
CO2 EMISSIONS CURRENT 5.4
CO2 EMISS CURR PER FLOOR AREA 69
CO2 EMISSIONS POTENTIAL 2.8
LIGHTING COST CURRENT 212
LIGHTING COST POTENTIAL 147
HEATING COST CURRENT 1449
HEATING COST POTENTIAL 1151
HOT WATER COST CURRENT 323
HOT WATER COST POTENTIAL 184
TOTAL FLOOR AREA 78
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 56
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 56% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical, extract only
ADDRESS 61 Meadow View Road, Kennington
LOCAL AUTHORITY LABEL Vale of White Horse
CONSTITUENCY LABEL Oxford West and Abingdon
POSTTOWN OXFORD
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2023-05-11 16:25:13
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100120921468
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000008
Address display