Energy Performance Certificate

16, Mant Close, Wickham, RG20 8HN

EPC Report

Energy rating

Current: 34 F | Potential: 118 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 F Current: 34 F 118 A Potential: 118 A

Environmental impact (CO₂)

Current: 21 | Potential: 96
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 21 Current: 21 96 Potential: 96
Field Value
LMK KEY 8600-1345-0629-4197-5283
ADDRESS1 16, Mant Close
ADDRESS2 Wickham
ADDRESS3
POSTCODE RG20 8HN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 34
POTENTIAL ENERGY EFFICIENCY 118
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2018-02-14
LOCAL AUTHORITY E06000037
CONSTITUENCY E14001376
COUNTY
LODGEMENT DATE 2018-02-15
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 21
ENVIRONMENT IMPACT POTENTIAL 96
ENERGY CONSUMPTION CURRENT 918
ENERGY CONSUMPTION POTENTIAL 13
CO2 EMISSIONS CURRENT 6.8
CO2 EMISS CURR PER FLOOR AREA 155
CO2 EMISSIONS POTENTIAL 0.1
LIGHTING COST CURRENT 66
LIGHTING COST POTENTIAL 37
HEATING COST CURRENT 1057
HEATING COST POTENTIAL 444
HOT WATER COST CURRENT 138
HOT WATER COST POTENTIAL 74
TOTAL FLOOR AREA 44
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 20
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 20% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 16, Mant Close, Wickham
LOCAL AUTHORITY LABEL West Berkshire
CONSTITUENCY LABEL Newbury
POSTTOWN NEWBURY
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2018-02-15 11:47:23
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 200004717736
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000008
Address display
Nation ew