Energy Performance Certificate

134, Thornton Road, M14 7WS

EPC Report

Energy rating

Current: 33 F | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 F Current: 33 F 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 42 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 88 Potential: 88
Field Value
LMK KEY 8600-0923-5529-4897-7553
ADDRESS1 134, Thornton Road
ADDRESS2
ADDRESS3
POSTCODE M14 7WS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 33
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-05-12
LOCAL AUTHORITY E08000003
CONSTITUENCY E14001353
COUNTY
LODGEMENT DATE 2015-05-12
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 406
ENERGY CONSUMPTION POTENTIAL 73
CO2 EMISSIONS CURRENT 4.7
CO2 EMISS CURR PER FLOOR AREA 69
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 69
LIGHTING COST POTENTIAL 45
HEATING COST CURRENT 1184
HEATING COST POTENTIAL 363
HOT WATER COST CURRENT 92
HOT WATER COST POTENTIAL 65
TOTAL FLOOR AREA 68
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 45
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 45% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 134, Thornton Road
LOCAL AUTHORITY LABEL Manchester
CONSTITUENCY LABEL Manchester Rusholme
POSTTOWN MANCHESTER
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2015-05-12 19:55:13
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 77113692
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000002
Address display
Nation ew