Energy Performance Certificate

14, Herbert Drive, Methwold, IP26 4PY

EPC Report

Energy rating

Current: 94 A | Potential: 97 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 94 A Current: 94 A 97 A Potential: 97 A

Environmental impact (CO₂)

Current: 91 | Potential: 97
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 91 Current: 91 97 Potential: 97
Field Value
LMK KEY 8595-6029-8150-0091-6906
ADDRESS1 14, Herbert Drive
ADDRESS2 Methwold
ADDRESS3
POSTCODE IP26 4PY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 94
POTENTIAL ENERGY EFFICIENCY 97
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-01-09
LOCAL AUTHORITY E07000146
CONSTITUENCY E14001497
COUNTY
LODGEMENT DATE 2015-01-20
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 91
ENVIRONMENT IMPACT POTENTIAL 97
ENERGY CONSUMPTION CURRENT 51
ENERGY CONSUMPTION POTENTIAL 10
CO2 EMISSIONS CURRENT 0.8
CO2 EMISS CURR PER FLOOR AREA 9
CO2 EMISSIONS POTENTIAL 0.1
LIGHTING COST CURRENT 58
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 348
HEATING COST POTENTIAL 318
HOT WATER COST CURRENT 184
HOT WATER COST POTENTIAL 119
TOTAL FLOOR AREA 88
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE triple, known data
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully triple glazed
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION System built, with external insulation
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.39
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 14, Herbert Drive, Methwold
LOCAL AUTHORITY LABEL King's Lynn and West Norfolk
CONSTITUENCY LABEL South West Norfolk
POSTTOWN THETFORD
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-01-20 11:51:29
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100090992408
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display
Nation ew