Energy Performance Certificate

1, Colemore Square, PO9 2BU

EPC Report

Energy rating

Current: 28 F | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 F Current: 28 F 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 25 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 Current: 25 76 Potential: 76
Field Value
LMK KEY 8593-3556-7729-1407-3913
ADDRESS1 1, Colemore Square
ADDRESS2
ADDRESS3
POSTCODE PO9 2BU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 28
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2019-11-05
LOCAL AUTHORITY E07000090
CONSTITUENCY E14001275
COUNTY
LODGEMENT DATE 2019-11-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 25
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 553
ENERGY CONSUMPTION POTENTIAL 119
CO2 EMISSIONS CURRENT 7.5
CO2 EMISS CURR PER FLOOR AREA 97
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 85
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 1424
HEATING COST POTENTIAL 573
HOT WATER COST CURRENT 92
HOT WATER COST POTENTIAL 50
TOTAL FLOOR AREA 77
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Colemore Square
LOCAL AUTHORITY LABEL Havant
CONSTITUENCY LABEL Havant
POSTTOWN HAVANT
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2019-11-05 21:53:26
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100060430489
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000008
Address display
Nation ew