Energy Performance Certificate

18, Manor Park, Watling Street Road, PR2 8LU

EPC Report

Energy rating

Current: 66 D | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 D Current: 66 D 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 68 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 Current: 68 80 Potential: 80
Field Value
LMK KEY 8577-6726-5040-4331-0992
ADDRESS1 18, Manor Park
ADDRESS2 Watling Street Road
ADDRESS3
POSTCODE PR2 8LU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 66
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2013-06-19
LOCAL AUTHORITY E07000123
CONSTITUENCY E14001433
COUNTY
LODGEMENT DATE 2013-07-09
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 68
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 232
ENERGY CONSUMPTION POTENTIAL 144
CO2 EMISSIONS CURRENT 2.5
CO2 EMISS CURR PER FLOOR AREA 44
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 49
LIGHTING COST POTENTIAL 37
HEATING COST CURRENT 485
HEATING COST POTENTIAL 319
HOT WATER COST CURRENT 88
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 56
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH 7.3
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 18, Manor Park, Watling Street Road
LOCAL AUTHORITY LABEL Preston
CONSTITUENCY LABEL Preston
POSTTOWN PRESTON
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2013-07-09 14:54:09
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100012405411
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000002
Address display
Nation ew