Energy Performance Certificate

32, New Molinnis, Bugle, PL26 8QL

EPC Report

Energy rating

Current: 46 E | Potential: 107 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 E Current: 46 E 107 A Potential: 107 A

Environmental impact (CO₂)

Current: 27 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 Current: 27 85 Potential: 85
Field Value
LMK KEY 8573-7629-0450-1665-3902
ADDRESS1 32, New Molinnis
ADDRESS2 Bugle
ADDRESS3
POSTCODE PL26 8QL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 46
POTENTIAL ENERGY EFFICIENCY 107
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2017-01-05
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001508
COUNTY
LODGEMENT DATE 2017-01-05
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 27
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 559
ENERGY CONSUMPTION POTENTIAL 75
CO2 EMISSIONS CURRENT 8
CO2 EMISS CURR PER FLOOR AREA 94
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 117
LIGHTING COST POTENTIAL 63
HEATING COST CURRENT 1020
HEATING COST POTENTIAL 505
HOT WATER COST CURRENT 233
HOT WATER COST POTENTIAL 97
TOTAL FLOOR AREA 85
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 12
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 12% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 32, New Molinnis, Bugle
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL St Austell and Newquay
POSTTOWN ST. AUSTELL
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2017-01-05 19:29:38
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100040143732
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000009
Address display
Nation ew