Energy Performance Certificate

6 Arnheim Houses, Canons Ashby Road, Moreton Pinkney, NN11 3SF

EPC Report

Energy rating

Current: 60 D | Potential: 110 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 D Current: 60 D 110 A Potential: 110 A

Environmental impact (CO₂)

Current: 64 | Potential: 109
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 109 Potential: 109
Field Value
LMK KEY 8571-6624-6910-3881-9902
ADDRESS1 6 Arnheim Houses
ADDRESS2 Canons Ashby Road
ADDRESS3 Moreton Pinkney
POSTCODE NN11 3SF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 60
POTENTIAL ENERGY EFFICIENCY 110
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2019-04-09
LOCAL AUTHORITY E06000062
CONSTITUENCY E14001490
COUNTY
LODGEMENT DATE 2019-04-09
TRANSACTION TYPE Stock condition survey
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 109
ENERGY CONSUMPTION CURRENT 279
ENERGY CONSUMPTION POTENTIAL -74
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 47
CO2 EMISSIONS POTENTIAL -0.7
LIGHTING COST CURRENT 59
LIGHTING COST POTENTIAL 46
HEATING COST CURRENT 464
HEATING COST POTENTIAL 360
HOT WATER COST CURRENT 397
HOT WATER COST POTENTIAL 264
TOTAL FLOOR AREA 60
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6 Arnheim Houses, Canons Ashby Road, Moreton Pinkney
LOCAL AUTHORITY LABEL West Northamptonshire
CONSTITUENCY LABEL South Northamptonshire
POSTTOWN DAVENTRY
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2019-04-09 15:30:11
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 10000459319
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000004
Address display
Nation ew