Energy Performance Certificate

22, Dolithel, Bryncrug, LL36 9RR

EPC Report

Energy rating

Current: 47 E | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 E Current: 47 E 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 26 | Potential: 49
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 49 Potential: 49
Field Value
LMK KEY 8567-7429-0600-1439-4922
ADDRESS1 22, Dolithel
ADDRESS2 Bryncrug
ADDRESS3
POSTCODE LL36 9RR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 47
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2013-01-21
LOCAL AUTHORITY W06000002
CONSTITUENCY W07000096
COUNTY
LODGEMENT DATE 2013-01-22
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 49
ENERGY CONSUMPTION CURRENT 477
ENERGY CONSUMPTION POTENTIAL 271
CO2 EMISSIONS CURRENT 10
CO2 EMISS CURR PER FLOOR AREA 86
CO2 EMISSIONS POTENTIAL 5.9
LIGHTING COST CURRENT 86
LIGHTING COST POTENTIAL 66
HEATING COST CURRENT 1116
HEATING COST POTENTIAL 720
HOT WATER COST CURRENT 263
HOT WATER COST POTENTIAL 94
TOTAL FLOOR AREA 122
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 69
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 69% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 22, Dolithel, Bryncrug
LOCAL AUTHORITY LABEL Gwynedd
CONSTITUENCY LABEL Dwyfor Meirionnydd
POSTTOWN TYWYN
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2013-01-22 00:07:12
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100100022524
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew