Energy Performance Certificate

3, The Pound, Syresham, NN13 5HG

EPC Report

Energy rating

Current: 57 D | Potential: 108 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 108 A Potential: 108 A

Environmental impact (CO₂)

Current: 37 | Potential: 94
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 Current: 37 94 Potential: 94
Field Value
LMK KEY 8565-7422-4619-1057-5902
ADDRESS1 3, The Pound
ADDRESS2 Syresham
ADDRESS3
POSTCODE NN13 5HG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 108
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-12-03
LOCAL AUTHORITY E06000062
CONSTITUENCY E14001490
COUNTY
LODGEMENT DATE 2015-12-07
TRANSACTION TYPE FiT application
ENVIRONMENT IMPACT CURRENT 37
ENVIRONMENT IMPACT POTENTIAL 94
ENERGY CONSUMPTION CURRENT 455
ENERGY CONSUMPTION POTENTIAL 29
CO2 EMISSIONS CURRENT 7.1
CO2 EMISS CURR PER FLOOR AREA 77
CO2 EMISSIONS POTENTIAL 0.4
LIGHTING COST CURRENT 70
LIGHTING COST POTENTIAL 65
HEATING COST CURRENT 1505
HEATING COST POTENTIAL 681
HOT WATER COST CURRENT 156
HOT WATER COST POTENTIAL 111
TOTAL FLOOR AREA 92
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 91
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters, Room heaters, electric
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 91% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, The Pound, Syresham
LOCAL AUTHORITY LABEL West Northamptonshire
CONSTITUENCY LABEL South Northamptonshire
POSTTOWN BRACKLEY
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2015-12-07 12:18:11
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100031169228
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000004
Address display
Nation ew