Energy Performance Certificate

58, Cranmer Street, Long Eaton, NG10 1NL

EPC Report

Energy rating

Current: 71 C | Potential: 93 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 93 A Potential: 93 A

Environmental impact (CO₂)

Current: 59 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 89 Potential: 89
Field Value
LMK KEY 8565-7020-4319-4077-7922
ADDRESS1 58, Cranmer Street
ADDRESS2 Long Eaton
ADDRESS3
POSTCODE NG10 1NL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 93
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-10-23
LOCAL AUTHORITY E07000036
CONSTITUENCY E14001228
COUNTY
LODGEMENT DATE 2015-11-25
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 229
ENERGY CONSUMPTION POTENTIAL 49
CO2 EMISSIONS CURRENT 4.1
CO2 EMISS CURR PER FLOOR AREA 41
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 118
LIGHTING COST POTENTIAL 62
HEATING COST CURRENT 1043
HEATING COST POTENTIAL 502
HOT WATER COST CURRENT 126
HOT WATER COST POTENTIAL 75
TOTAL FLOOR AREA 101
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 10
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 10% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 58, Cranmer Street, Long Eaton
LOCAL AUTHORITY LABEL Erewash
CONSTITUENCY LABEL Erewash
POSTTOWN NOTTINGHAM
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2015-11-25 06:22:59
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100030148363
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000004
Address display
Nation ew