Energy Performance Certificate

140, Shirley Towers, Milner Court, SO15 5PF

EPC Report

Energy rating

Current: 64 D | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 57 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 79 Potential: 79
Field Value
LMK KEY 8563-7923-4130-0235-2902
ADDRESS1 140, Shirley Towers
ADDRESS2 Milner Court
ADDRESS3
POSTCODE SO15 5PF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2017-07-05
LOCAL AUTHORITY E06000045
CONSTITUENCY E14001500
COUNTY
LODGEMENT DATE 2017-10-05
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 255
ENERGY CONSUMPTION POTENTIAL 127
CO2 EMISSIONS CURRENT 3.2
CO2 EMISS CURR PER FLOOR AREA 45
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 65
LIGHTING COST POTENTIAL 65
HEATING COST CURRENT 522
HEATING COST POTENTIAL 228
HOT WATER COST CURRENT 116
HOT WATER COST POTENTIAL 116
TOTAL FLOOR AREA 72
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Charging system linked to use of community heating, programmer and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 88
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION System built, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 88% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 3.42
FLOOR HEIGHT 2.32
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 140, Shirley Towers, Milner Court
LOCAL AUTHORITY LABEL Southampton
CONSTITUENCY LABEL Southampton Test
POSTTOWN SOUTHAMPTON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2017-10-05 10:38:21
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100062507226
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000008
Address display
Nation ew