Energy Performance Certificate

26, Heath View, N2 0QA

EPC Report

Energy rating

Current: 41 E | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 E Current: 41 E 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 28 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 Current: 28 65 Potential: 65
Field Value
LMK KEY 8553-7629-4230-4934-5926
ADDRESS1 26, Heath View
ADDRESS2
ADDRESS3
POSTCODE N2 0QA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 41
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2017-01-24
LOCAL AUTHORITY E09000003
CONSTITUENCY E14001238
COUNTY
LODGEMENT DATE 2017-01-25
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 28
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 558
ENERGY CONSUMPTION POTENTIAL 213
CO2 EMISSIONS CURRENT 7.3
CO2 EMISS CURR PER FLOOR AREA 94
CO2 EMISSIONS POTENTIAL 2.8
LIGHTING COST CURRENT 100
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 981
HEATING COST POTENTIAL 476
HOT WATER COST CURRENT 321
HOT WATER COST POTENTIAL 95
TOTAL FLOOR AREA 78
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 29
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 29% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 26, Heath View
LOCAL AUTHORITY LABEL Barnet
CONSTITUENCY LABEL Finchley and Golders Green
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2017-01-25 09:12:44
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 200058187
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000007
Address display
Nation ew