Energy Performance Certificate

28, Silverthorn Drive, HP3 8BU

EPC Report

Energy rating

Current: 83 B | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 B Current: 83 B 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 77 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 77 Potential: 77
Field Value
LMK KEY 8545-6822-8919-4832-5922
ADDRESS1 28, Silverthorn Drive
ADDRESS2
ADDRESS3
POSTCODE HP3 8BU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 83
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-12-22
LOCAL AUTHORITY E07000096
CONSTITUENCY E14001278
COUNTY
LODGEMENT DATE 2015-12-24
TRANSACTION TYPE FiT application
ENVIRONMENT IMPACT CURRENT 77
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 93
ENERGY CONSUMPTION POTENTIAL 93
CO2 EMISSIONS CURRENT 9.7
CO2 EMISS CURR PER FLOOR AREA 17
CO2 EMISSIONS POTENTIAL 9.7
LIGHTING COST CURRENT 174
LIGHTING COST POTENTIAL 174
HEATING COST CURRENT 2703
HEATING COST POTENTIAL 2703
HOT WATER COST CURRENT 125
HOT WATER COST POTENTIAL 125
TOTAL FLOOR AREA 586
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and at least two room thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE triple glazing
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 11
NUMBER HEATED ROOMS 11
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully triple glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity and internal insulation
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and at least two room thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.61
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical, extract only
ADDRESS 28, Silverthorn Drive
LOCAL AUTHORITY LABEL Dacorum
CONSTITUENCY LABEL Hemel Hempstead
POSTTOWN HEMEL HEMPSTEAD
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-12-24 13:25:40
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 53
LOW ENERGY FIXED LIGHT COUNT 53
UPRN 100080704214
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display
Nation ew