Energy Performance Certificate

6, Queens Road, Tisbury, SP3 6JN

EPC Report

Energy rating

Current: 58 D | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 46 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 79 Potential: 79
Field Value
LMK KEY 8527-7326-0270-9954-5906
ADDRESS1 6, Queens Road
ADDRESS2 Tisbury
ADDRESS3
POSTCODE SP3 6JN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-06-04
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001460
COUNTY
LODGEMENT DATE 2013-06-04
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 246
ENERGY CONSUMPTION POTENTIAL 69
CO2 EMISSIONS CURRENT 5.0
CO2 EMISS CURR PER FLOOR AREA 62
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 51
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 722
HEATING COST POTENTIAL 398
HOT WATER COST CURRENT 235
HOT WATER COST POTENTIAL 98
TOTAL FLOOR AREA 81
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 91
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 90
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 90% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, Queens Road, Tisbury
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL Salisbury
POSTTOWN SALISBURY
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2013-06-04 12:27:50
TENURE Unknown
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100121053160
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000009
Address display
Nation ew