Energy Performance Certificate

83, Gloucester Road, Staple Hill, BS16 4SL

EPC Report

Energy rating

Current: 59 D | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 54 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 Current: 54 73 Potential: 73
Field Value
LMK KEY 8522-6926-9260-3849-7906
ADDRESS1 83, Gloucester Road
ADDRESS2 Staple Hill
ADDRESS3
POSTCODE BS16 4SL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2012-06-01
LOCAL AUTHORITY E06000025
CONSTITUENCY E14001133
COUNTY
LODGEMENT DATE 2012-06-01
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 54
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 223
ENERGY CONSUMPTION POTENTIAL 122
CO2 EMISSIONS CURRENT 5.4
CO2 EMISS CURR PER FLOOR AREA 43
CO2 EMISSIONS POTENTIAL 3.0
LIGHTING COST CURRENT 107
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 867
HEATING COST POTENTIAL 665
HOT WATER COST CURRENT 90
HOT WATER COST POTENTIAL 91
TOTAL FLOOR AREA 125
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 16
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 16% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 83, Gloucester Road, Staple Hill
LOCAL AUTHORITY LABEL South Gloucestershire
CONSTITUENCY LABEL Bristol North East
POSTTOWN BRISTOL
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2012-06-01 23:37:55
TENURE
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 532714
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000009
Address display
Nation ew