Energy Performance Certificate

52, The Beck, Elford, B79 9BP

EPC Report

Energy rating

Current: 56 D | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 D Current: 56 D 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 47 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 85 Potential: 85
Field Value
LMK KEY 8507-5341-0529-1507-5243
ADDRESS1 52, The Beck
ADDRESS2 Elford
ADDRESS3
POSTCODE B79 9BP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 56
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2014-02-04
LOCAL AUTHORITY E07000194
CONSTITUENCY E14001538
COUNTY
LODGEMENT DATE 2014-02-04
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 262
ENERGY CONSUMPTION POTENTIAL 62
CO2 EMISSIONS CURRENT 5.2
CO2 EMISS CURR PER FLOOR AREA 60
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 60
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 1014
HEATING COST POTENTIAL 486
HOT WATER COST CURRENT 176
HOT WATER COST POTENTIAL 107
TOTAL FLOOR AREA 88
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 95
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 85
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 85% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 52, The Beck, Elford
LOCAL AUTHORITY LABEL Lichfield
CONSTITUENCY LABEL Tamworth
POSTTOWN TAMWORTH
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2014-02-04 13:07:28
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 100031712661
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000005
Address display
Nation ew