Energy Performance Certificate

1 Sidmouth Lodge, The Drive, Bicton, East Budleigh, EX9 7BH

EPC Report

Energy rating

Current: 25 F | Potential: 113 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 F Current: 25 F 113 A Potential: 113 A

Environmental impact (CO₂)

Current: 13 | Potential: 93
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 13 Current: 13 93 Potential: 93
Field Value
LMK KEY 8506-7136-3922-8797-2203
ADDRESS1 1 Sidmouth Lodge
ADDRESS2 The Drive
ADDRESS3 Bicton, East Budleigh
POSTCODE EX9 7BH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 25
POTENTIAL ENERGY EFFICIENCY 113
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2020-02-17
LOCAL AUTHORITY E07000040
CONSTITUENCY E14001232
COUNTY
LODGEMENT DATE 2020-02-19
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 13
ENVIRONMENT IMPACT POTENTIAL 93
ENERGY CONSUMPTION CURRENT 808
ENERGY CONSUMPTION POTENTIAL -7
CO2 EMISSIONS CURRENT 8.4
CO2 EMISS CURR PER FLOOR AREA 137
CO2 EMISSIONS POTENTIAL -0.1
LIGHTING COST CURRENT 75
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 1533
HEATING COST POTENTIAL 462
HOT WATER COST CURRENT 234
HOT WATER COST POTENTIAL 99
TOTAL FLOOR AREA 62
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 25 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.94
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1 Sidmouth Lodge, The Drive, Bicton, East Budleigh
LOCAL AUTHORITY LABEL East Devon
CONSTITUENCY LABEL Exmouth and Exeter East
POSTTOWN BUDLEIGH SALTERTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2020-02-19 15:28:31
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 10000251060
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000009
Address display
Nation ew