Energy Performance Certificate

21, Rectory Gardens, B36 9DG

EPC Report

Energy rating

Current: 7 G | Potential: 50 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 7 G Current: 7 G 50 E Potential: 50 E

Environmental impact (CO₂)

Current: 20 | Potential: 26
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 20 Current: 20 26 Potential: 26
Field Value
LMK KEY 8506-6892-0129-9397-3343
ADDRESS1 21, Rectory Gardens
ADDRESS2
ADDRESS3
POSTCODE B36 9DG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 7
POTENTIAL ENERGY EFFICIENCY 50
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2014-07-11
LOCAL AUTHORITY E08000029
CONSTITUENCY E14001095
COUNTY
LODGEMENT DATE 2014-07-11
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 20
ENVIRONMENT IMPACT POTENTIAL 26
ENERGY CONSUMPTION CURRENT 681
ENERGY CONSUMPTION POTENTIAL 594
CO2 EMISSIONS CURRENT 9.1
CO2 EMISS CURR PER FLOOR AREA 121
CO2 EMISSIONS POTENTIAL 8.0
LIGHTING COST CURRENT 93
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 2038
HEATING COST POTENTIAL 935
HOT WATER COST CURRENT 348
HOT WATER COST POTENTIAL 133
TOTAL FLOOR AREA 76
ENERGY TARIFF Unknown
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 90
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 12
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 12% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH 6.57
FLOOR HEIGHT 2.33
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 21, Rectory Gardens
LOCAL AUTHORITY LABEL Solihull
CONSTITUENCY LABEL Birmingham Hodge Hill and Solihull North
POSTTOWN BIRMINGHAM
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2014-07-11 20:32:49
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100071007166
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000005
Address display
Nation ew