Energy Performance Certificate

8d, Sussex Heights, St. Margarets Place, BN1 2FQ

EPC Report

Energy rating

Current: 57 D | Potential: 69 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 69 C Potential: 69 C

Environmental impact (CO₂)

Current: 42 | Potential: 49
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 49 Potential: 49
Field Value
LMK KEY 8506-5833-3129-8627-4953
ADDRESS1 8d, Sussex Heights
ADDRESS2 St. Margarets Place
ADDRESS3
POSTCODE BN1 2FQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 69
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2015-01-27
LOCAL AUTHORITY E06000043
CONSTITUENCY E14001130
COUNTY
LODGEMENT DATE 2015-01-27
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 49
ENERGY CONSUMPTION CURRENT 368
ENERGY CONSUMPTION POTENTIAL 314
CO2 EMISSIONS CURRENT 6.5
CO2 EMISS CURR PER FLOOR AREA 62
CO2 EMISSIONS POTENTIAL 5.5
LIGHTING COST CURRENT 106
LIGHTING COST POTENTIAL 73
HEATING COST CURRENT 791
HEATING COST POTENTIAL 616
HOT WATER COST CURRENT 296
HOT WATER COST POTENTIAL 155
TOTAL FLOOR AREA 104
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 56
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 56% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 20.49
FLOOR HEIGHT 2.56
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 8d, Sussex Heights, St. Margarets Place
LOCAL AUTHORITY LABEL Brighton and Hove
CONSTITUENCY LABEL Brighton Pavilion
POSTTOWN BRIGHTON
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2015-01-27 20:05:59
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 22046332
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000008
Address display
Nation ew